Product

00

Search product

Usage

















Target gas

























Category




Applicable Products:
Gas Sensor

SB-11A-00

Usage:Home gas leak detector/Industrial leak detector
Target gas:LNG(Methane)/LPG(Propane, butane)/H2
Target gas LNG(Methane),LPG(Propane, butane),H2
Description Compact, low power consumption, excellent responsiveness, and highly sensitive sensor for various hydrocarbons.
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 0.9V ± 5% Circuit voltage/less than DC 5V
Power consumption 120mW
Filter Not included
Size φ7.6 x 13.4mm
Weight 0.6g
SB-11A-00
Related item
Gas Sensor

SB-12A-00

Usage:Home gas leak detector/Industrial leak detector
Target gas:LNG(Methane)
Target gas LNG(Methane),H2
Description Compact, low power consumption sensor with excellent methane selectivity.
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 0.9V ± 5% Circuit voltage/less than DC 5V
Power consumption 120mW
Filter Charcoal filter
Size φ10.0 x 20mm
Weight 1.2g
SB-12A-00
Related item
FIS3031-xx
EVM-SB-01-xx
SCK-03
Gas Sensor

SB-15-00

Usage:Industrial leak detector
Target gas:LPG(Propane, butane)
Target gas LPG(Propane, butane)
Description Compact, low power consumption, excellent responsiveness, and highly sensitive sensor for propane LPG/butane
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 0.9V ± 5% Circuit voltage/less than DC 5V
Power consumption 120mW
Filter Not included
Size φ7.6 x 13.4mm
Weight 0.6g
SB-15-00
Related item
EVM-SB-01-xx
SCK-03
Gas Sensor

SB-500-12

Usage:Home gas leak detector/Industrial leak detector
Target gas:CO
Target gas CO
Description Sensor with high sensitivity and long life to carbon monoxide. UL compliant product
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 0.9V x 5sec. + DC 0.2V x 20sec. 
Circuit voltage/less than DC 5V
Power consumption Average:34mW
Filter Charcoal filter
Size φ10.0 x 20mm
Weight 1.2g
SB-500-12
Related item
FIS3051-xx
SCK-03
Gas Sensor

SB-95-12

Usage:Home gas leak detector/Industrial leak detector
Target gas:LNG(Methane)/CO
Target gas LNG(Methane)、CO
Description A sensor that can selectively detect methane and CO only with one sensor element. UL compliant product
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 0.9V x 5sec. + DC 0.2V x 20sec. 
Circuit voltage/less than DC 5V
Power consumption Average:34mW
Filter Charcoal filter
Size φ10.0 x 20mm
Weight 1.2g
SB-95-12
Related item
FIS3001-xx
SCK-03
Gas Sensor

SB-19-00

Usage:Industrial leak detector
Target gas:H2
Target gas H2
Description Compact, low power consumption sensor with excellent H2 selectivity.
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 0.9V ± 5% Circuit voltage/less than DC 5V
Power consumption 120mW
Filter Not included
Size φ7.6 x 13.4mm
Weight 0.6g
SB-19-00
Related item
EVM-SB-01-xx
SCK-03
Gas Sensor

SB-42A-00

Usage:Refrigerant gas/Industrial leak detector
Target gas:Refrigerant(R32/R410a/R407C/R1234yf/R454B/R454C/Others)
Target gas Refrigerant gas(R32/R410a/R407C/R1234yf/R454C/R454B/R22)
Description Compact, low power consumption, highly responsive sensor that is highly sensitive to various refrigerant gases.
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 0.9V ± 5% Circuit voltage/less than DC 5V
Power consumption 120mW
Filter Not included
Size φ7.6 x 13.4mm
Weight 0.6g
SB-42A-00
Related item
EVM-SB-01-xx
SCK-03
Gas Sensor

SB-43A-00

Usage:Refrigerant gas/Industrial leak detector
Target gas:Refrigerant(R32/R410a/R407C/R1234yf/R454B/R454C/R290/Others)
Target gas Refrigerant gas(R32/R410a/R407C/R1234yf/R454C/R454B/R22)
Description Compact sensor that is highly sensitive to various refrigerant gases with low power consumption and excellent durability
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 0.9V ± 5% Circuit voltage/less than DC 5V
Power consumption 120mW
Filter Silica filter
Size φ10.0 x 20mm
Weight 1.2g
SB-43-00
Related item
EVM-SB-01-xx
SCK-03
Gas Sensor

SB-53-01

Usage:Research・Analysis - Enviromental measurement
Target gas:Ammonia
Target gas Ammonia
Description Compact sensor that is highly sensitive to ammonia with low power consumption and excellent response
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 0.9V ± 5% Circuit voltage/less than DC 5V
Power consumption 120mW
Filter Not included
Size φ7.6 x 13.4mm
Weight 0.6g
SB-53-00
Related item
FIS3091-xx
EVM-SB-01-xx
SCK-03
Gas Sensor

SB-AQ1-06

Usage:Automobile - Inside air/Air quality - Air purifiers
Target gas:H2/Ethanol/VOC
Target gas H2、Ethanol、VOC
Description Compact sensor that is highly sensitive to gas generated in a living space with low power consumption and excellent response
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 0.9V ± 5% Circuit voltage/less than DC 5V
Power consumption 120mW
Filter Not included
Size φ7.6 x 13.4mm
Weight 0.6g
SB-AQ1-06
Related item
FIS3072-xx
EVM-SB-01-xx
SCK-03
Gas Sensor

SB-30-04

Usage:Alcohol checker
Target gas:Ethanol/VOC/Halitosis
Target gas VOC、Breath gas
Description Sensor that is highly stable after power-on and highly sensitive to alcohol and various VOCs. Suitable for intermittent operation products.
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 0.9V ± 5% Circuit voltage/less than DC 5V
Power consumption 120mW
Filter Not included
Size φ7.6 x 13.4mm
Weight 0.6g
SB-30-04
Related item
EVM-SB-01-xx
SCK-03
Gas Sensor

SP3S-AQ2-01

Usage:Automobile - Inside air/Air quality - Air purifiers/Home appliances/Alcohol checker
Target gas:CO/Ethanol/VOC
Target gas CO、Ethanol、VOC
Description Compact sensor that is highly sensitive to gas generated in a living space. Circuit design is easier than SB- series.
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 5.0V ± 4% Circuit voltage/less than DC 5V
Power consumption 400mW
Filter Not included
Size φ7.6 x 13.4mm
Weight 0.6g
SP3S-AQ2-01
Related item
EVM-SP-02-SP3S
Gas Sensor

SP3-61-00

Usage:Air quality - Ozone/Home appliances
Target gas:Ozone
Target gas Ozone
Description Sensor that is highly sensitive to ozone. Circuit design is easier than SB- series.
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 5.0V ± 4% Circuit voltage/less than DC 5V
Power consumption 400mW
Filter Not included
Size φ14.0 x 18.0mm
Weight 1.2g
SP3-61-00
Related item
A01020-61
A1320301-SP361-02
Sensor Module

EVM-SB-01-xx

Usage:-
Target gas:-
Description Evaluation module for SB series sensor. (except SB-500-12,SB-96-00,SB-95-12)
Sensing principal of mounted gas sensor Semiconductor type
Power supply DC5V ± 4%
Signal output Voltage(0 - 5 V)
Waterproof case Not included
Size Circuit board size:37×22㎜
Cable length:10㎝
EVM-SB-01-xx
Related item
Sensor Module

EVM-SP-01-xx

Usage:-
Target gas:-
Description Evaluation module for SP series sensor.
Sensing principal of mounted gas sensor Semiconductor type
Power supply DC5V ± 4%
Signal output Voltage(0 - 5 V)
Waterproof case Not included
Size Circuit board size:37×22㎜
Cable length:10㎝
EVM-SP-01-xx
Related item
Sensor Module

EVM-SP-02-SP3S

Usage:Automobile - Inside air/Air quality - Air purifiers/Alcohol checker
Target gas:-
Target gas CO、Ethanol、VOC
Description Evaluation module for SP3S-AQ2-01 to measure sensor output.
Sensing principal of mounted gas sensor Semiconductor type
Power consumption 210mW
Power supply DC5V ± 4%
Current consumption 42mA
Signal output Voltage(0 - 5 V)
Waterproof case Not included
Size 37×22×13.4(H)㎜
Cable length:10㎝
Weight 5g
EVM-SP-02-SP3S
Related item
SP3S-AQ2-01
Sensor Module

A1320301-SP61-02

Usage:Air quality - Ozone/Industrial leak detector
Target gas:Ozone
Target gas Ozone
Description Module for measuring ozone gas.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0 - 250 ppb
Power consumption 600mW
Power supply DC5V ± 5%
Current consumption 120mA
Signal output Voltage(0 - 5 V)
Waterproof case Not included
Size 51 (W) x 37 (D) x 22 (H) mm
Weight 15g
Sensor Module

A1320301-SP61-02F

Usage:Air quality - Ozone/Industrial leak detector
Target gas:Ozone
Target gas Ozone
Description Module for measuring ozone gas with fan and cable.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0 - 250 ppb
Power consumption 700mW
Power supply DC5V ± 5%
Current consumption 140mA
Signal output Voltage(0 - 5 V)
Waterproof case Not included
Size 65 (W) x 100 (D) x 35 (H) mm
Weight 90g
A1320301-SP61-02F
Related item
A1320301-SP61-02
Sensor Module

A01020-61

Usage:Air quality - Ozone
Target gas:Ethanol
Target gas Ozone
Description Evaluation module for SP3-61-00. This module is for sensor output measurement.
Size 22 x 37 x 13(H)mm
Weight 5g
A01020-61
Related item
SP3-61-00
その他

A051020H-001

Usage:Air quality - Ozone
Target gas:Ozone
Description Cable for ozone module.
   
 
Sensor Module

FIS3001-00NC-03/50

Usage:Home gas leak detector
Target gas:LNG(Methane)/CO
Target gas LNG(Methane)、CO
Description Gas calibrated module (mounted SB-95-12) without waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range CH4 0, 0.03-1 %
CO 0, 30-1000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3001-00NC-03/50
Related item
SB-95-12
Sensor Module

FIS3001-00C4-03/50

Usage:Home gas leak detector
Target gas:LNG(Methane)/CO
Target gas LNG(Methane)、CO
Description Gas calibrated module (mounted SB-95-12) with waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range CH4 0, 0.03-1 %
CO 0, 30-1000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3001-00C4-03/50
Related item
SB-95-12
Sensor Module

FIS3031-00NC-50

Usage:Home gas leak detector
Target gas:LNG(Methane)
Target gas LNG(Methane)
Description Gas calibrated module (mounted SB-12A) without waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 0.03-1 %
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3031-00NC-50
Related item
SB-12A-00
Sensor Module

FIS3031-00C4-50

Usage:Home gas leak detector
Target gas:LNG(Methane)
Target gas LNG(Methane)
Description Gas calibrated module (mounted SB-12A) with waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 0.03-1 %
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3031-00C4-50
Related item
SB-12A-00
Sensor Module

FIS3051-00NC-03

Usage:Home gas leak detector
Target gas:CO
Target gas CO
Description Gas calibrated module (mounted SB-500-12) without waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 30-1000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3051-00NC-03
Related item
SB-500-12
Sensor Module

FIS3051-00C4-03

Usage:Home gas leak detector
Target gas:CO
Target gas CO
Description Gas calibrated module (mounted SB-500-12) with waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 30-1000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3051-00C4-03
Related item
SB-500-12
Sensor Module

FIS3062-00NC-20

Usage:Refrigerant gas/Home appliances
Target gas:LPG(Propane, butane)
Target gas LPG(Propane, butane)
Description Gas calibrated module (mounted SB-15C) without waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range Isobutane 0, 300-10000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3062-00NC-20
Related item
Sensor Module

FIS3062-00C4-20

Usage:Refrigerant gas/Home appliances
Target gas:LPG(Propane, butane)
Target gas LPG(Propane, butane)
Description Gas calibrated module (mounted SB-15C) with waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range Isobutane 0, 300-10000 ppm
Power supply DC5V ±5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3062-00C4-20
Related item
Sensor Module

FIS3072-00NC-10

Usage:-
Target gas:H2/Ethanol/VOC
Target gas H2、Ethanol、VOC
Description Gas calibrated module (mounted SB-AQ1) without waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 30-1000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3072-00NC-10
Related item
SB-AQ1-06
Sensor Module

FIS3072-00C4-10

Usage:-
Target gas:H2/Ethanol/VOC
Target gas H2、Ethanol、VOC
Description Gas calibrated module (mounted SB-AQ1) with waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 30-1000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3072-00C4-10
Related item
SB-AQ1-06
Sensor Module

FIS3082-00NC-50

Usage:Refrigerant gas/Home appliances/Industrial leak detector
Target gas:Refrigerant(R410a)
Target gas Refrigerant gas(R410a)
Description Gas calibrated module for R410a without waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 0.03-1 %
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3082-00NC-50
Related item
Sensor Module

FIS3082-00C4-50

Usage:Refrigerant gas/Home appliances/Industrial leak detector
Target gas:Refrigerant(R410a)
Target gas Refrigerant gas(R410a)
Description Gas calibrated module for R410a with waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 0.03-1 %
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3082-00C4-50
Related item
Sensor Module

FIS3091-00NC-03

Usage:Refrigerant gas/Home appliances/Industrial leak detector
Target gas:Ammonia
Target gas Ammonia
Description Gas calibrated module (mounted SB-53) without waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 30-500 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3091-00NC-03
Related item
SB-53-01
Sensor Module

FIS3091-00C4-03

Usage:Refrigerant gas/Home appliances/Industrial leak detector
Target gas:Ammonia
Target gas Ammonia
Description Gas calibrated module (mounted SB-53) with waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 30-500 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3091-00C4-03
Related item
SB-53-01
Sensor Module

FIS3001-99NC-03/50

Usage:Home gas leak detector
Target gas:LNG(Methane)/CO
Target gas LNG(Methane)、CO
Description Gas calibrated module (mounted SB-95-12) without waterproof case. Concentration output function included.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range CH4 0, 0.03-1 %
CO 0, 30-1000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3001-99NC-03/50
Related item
SB-95-12
Sensor Module

FIS3001-99C4-03/50

Usage:Home gas leak detector
Target gas:LNG(Methane)/CO
Target gas LNG(Methane)、CO
Description Gas calibrated module (mounted SB-95-12) with waterproof case. Concentration output function included.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range CH4 0, 0.03-1 %
CO 0, 30-1000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3001-99C4-03/50
Related item
SB-95-12
Sensor Module

FIS3031-99NC-30/50

Usage:Home gas leak detector
Target gas:LNG(Methane)
Target gas LNG(Methane)
Description Gas calibrated module (mounted SB-12A) without waterproof case. Concentration output function included.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 0.03-1 %
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3031-99NC-30/50
Related item
SB-12A-00
Sensor Module

FIS3031-99C4-30/50

Usage:Home gas leak detector
Target gas:LNG(Methane)
Target gas LNG(Methane)
Description Gas calibrated module (mounted SB-12A) with waterproof case. Concentration output function included.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 0.03-1 %
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3031-99C4-30/50
Related item
SB-12A-00
Sensor Module

FIS3051-99NC-01/03

Usage:Home gas leak detector
Target gas:CO
Target gas CO
Description Gas calibrated module (mounted SB-500-12) without waterproof case. Concentration output function included.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 30-1000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3051-99NC-01/03
Related item
SB-500-12
Sensor Module

FIS3051-99C4-01/03

Usage:Home gas leak detector
Target gas:CO
Target gas CO
Description Gas calibrated module (mounted SB-500-12) with waterproof case. Concentration output function included.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 30-1000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3051-99C4-01/03
Related item
SB-500-12
Sensor Module

FIS3062-99NC-10/20

Usage:Refrigerant gas/Home appliances
Target gas:LPG(Propane, butane)
Target gas LPG(Propane, butane)
Description Gas calibrated module (mounted SB-15C) without waterproof case. Concentration output function included .
Sensing principal of mounted gas sensor Semiconductor type
Measurement range Isobutane 0, 300-10000 ppm
Power supply DC5V ±5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3062-99NC-10/20
Related item
Sensor Module

FIS3062-99C4-10/20

Usage:Refrigerant gas/Home appliances
Target gas:LPG(Propane, butane)
Target gas LPG(Propane, butane)
Description Gas calibrated module (mounted SB-15C) with waterproof case. Concentration output function included.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range Isobutane 0, 300-10000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3062-99C4-10/20
Related item
Sensor Module

FIS3072-99NC-03/10

Usage:
Target gas:H2/Ethanol/VOC
Target gas H2、Ethanol、VOC
Description Gas calibrated module (mounted SB-AQ1) without waterproof case. Concentration output function included.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 30-1000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3072-99NC-03/10
Related item
SB-AQ1-06
Sensor Module

FIS3072-99C4-03/10

Usage:
Target gas:H2/Ethanol/VOC
Target gas H2、Ethanol、VOC
Description Gas calibrated module (mounted SB-AQ1) with waterproof case. Concentration output function included.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 30-1000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3072-99C4-03/10
Related item
SB-AQ1-06
Sensor Module

FIS3082-99NC-10/50

Usage:Refrigerant gas/Home appliances/Industrial leak detector
Target gas:Refrigerant(R410a)
Target gas Refrigerant gas(R410a)
Description Gas calibrated module for R410a without waterproof case. Concentration output function included .
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 0.03-1 %
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3082-99NC-10/50
Related item
Sensor Module

FIS3082-99C4-10/50

Usage:Refrigerant gas/Home appliances/Industrial leak detector
Target gas:Refrigerant(R410a)
Target gas Refrigerant gas(R410a)
Description Gas calibrated module for R410a with waterproof case. Concentration output function included .
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 0.03-1 %
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3082-99C4-10/50
Related item
Sensor Module

FIS3091-99NC-01/03

Usage:Refrigerant gas/Home appliances/Industrial leak detector
Target gas:Ammonia
Target gas Ammonia
Description Gas calibrated module (mounted SB-53) without waterproof case. Concentration output function included.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 30-500 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3091-99NC-01/03
Related item
SB-53-01
Sensor Module

FIS3091-99C4-01/03

Usage:Refrigerant gas/Home appliances/Industrial leak detector
Target gas:Ammonia
Target gas Ammonia
Description Gas calibrated module (mounted SB-53) with waterproof case. Concentration output function included.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 30-500 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3091-99C4-01/03
Related item
SB-53-01
Sensor Module

FIS5084-01NC

Usage:Refrigerant gas/Home appliances
Target gas:Refrigerant(R32)
Target gas Refrigerant gas(R32)
Description IEC compliant product. Gas calibrated module (mounted SB-43A) without waterproof case.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 2000-10000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 40mA
Signal output Alarm output
Waterproof case Not included
Size 26 x 26 x 20(H)mm
Weight 5g
FIS5084-01NC
Related item
SB-43A-00
Sensor Module

FIS5084-01C1

Usage:Refrigerant gas/Home appliances
Target gas:Refrigerant(R32)
Target gas Refrigerant gas(R32)
Description IEC compliant product. Gas calibrated module (mounted SB-43A) with waterproof case.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 2000-10000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 40mA
Signal output Alarm output
Waterproof case Included
Size 53 x 30 x 23.5(H)mm
Weight 11g
FIS5084-01C1
Related item
SB-43A-00
その他

SCK-03

Usage:-
Target gas:-
Description Gas sensor socket for SB series, SP3S-AQ2-01, SP3-61
Size 12.6×7.4×10.6(H)㎜
Weight 1.3g
SCK-03
Related item
SB series
SP3S-AQ2-01
SP3-61-
Application

OralChroma CHM-2

Usage:Breath analysis - Oral Chroma
Target gas:Sulfide (Methyl mercaptan・ Dimethyl sulfide)/Hydrogen sulfide
Target gas Hydrogen sulfide, Methyl mercaptan, Dimethyl sulfide
Description This device separates VSC in 3 element gases and measures its concentration. UL/CE compliant product.
Measurement range Hydrogen sulfide 50 - 1000 ppb
Methyl mercaptan 50 - 1000 ppb
Dimethyl sulfide 50 - 1000 ppb
Measuring time 4 min.
Carrier gas Filtered clean ambient air
Detector Semiconductor gas sensor
Sampling gas amount 1cc
Power supply AC 100V 
Current consumption 27VA (Max.60VA)
Signal output USB/Bluetooth
Size 280 (W) x 385 (D) x 170 (H)
Weight 4kg
OralChroma CHM-2
Related item
Application

SGC(Sensor Gas Chromatograph)
ODSA-P3-A

Usage:Research・Analysis - Enviromental measurement/Breath analysis - Others
Target gas:Sulfide (Methyl mercaptan・ Dimethyl sulfide)/Hydrogen sulfide
Target gas Hydrogen sulfide, Methanethiol, Dimethyl sulfide
Description Hydrogen sulfide, methanethiol, and dimethyl-sulfide can be separated and detected at the ppb level without concentrating the sample.
Measurement range Hydrogen sulfide 2-1000 ppb
Methanethiol 5-1000 ppb
Dimethyl sulfide 5-1000 ppb
Measuring time 4 min.
Carrier gas Filtered clean ambient air
Detector Semiconductor gas sensor
Sampling gas amount 2cc
Power supply AC 100V  or AC 220V
Current consumption Approx. 100VA  
Signal output USB
Size 260(W)×135(H)×340(D)mm
Weight 6.2kg
SGC(Sensor Gas Chromatograph) ODSA-P3-A
Related item
Exhaled breath bag
Application

SGC(Sensor Gas Chromatograph)
SGHA-P3-A

Usage:Automobile - Others/Research・Analysis - Enviromental measurement/Research・Analysis - Hydrogen embrittlement
Target gas:H2/CO
Target gas H2、CO
Description H2 and CO can be separated and detected at the ppb level without concentrating sample. (for low concentration)
Measurement range H2 10-10000 ppb
CO 50-10000 ppb
Measuring time 2 min.
Carrier gas Filtered clean ambient air
Detector Semiconductor gas sensor
Sampling gas amount 1cc
Power supply AC 100V  or AC 220V
Current consumption Approx. 100VA  
Signal output USB
Size 260(W)×135(H)×340(D)mm
Weight 6.2kg
SGC(Sensor Gas Chromatograph) SGHA-P3-A
Related item
Exhaled breath bag
Application

SGC(Sensor Gas Chromatograph)
SGHA-P3-B

Usage:Automobile - Others/Research・Analysis - Enviromental measurement/Research・Analysis - Hydrogen embrittlement/Breath analysis - Others
Target gas:H2/CO
Target gas H2、CO
Description H2 and CO can be separated and detected at the ppm level without concentrating sample. (for high concentration)
Measurement range H2 1000-100000 ppb
CO: 1000-100000 ppb
Measuring time 4 min.
Carrier gas Filtered clean ambient air
Detector Semiconductor gas sensor
Sampling gas amount 1cc
Power supply AC 100V  or AC 220V
Current consumption Approx. 100VA  
Signal output USB
Size 260(W)×135(H)×340(D)mm
Weight 6.2kg
SGC(Sensor Gas Chromatograph) SGHA-P3-B
Related item
Exhaled breath bag
Application

SGC(Sensor Gas Chromatograph)
SGEA-P3-A

Usage:Research・Analysis - Enviromental measurement/Research・Analysis - Hydrogen embrittlement/Breath analysis - Others
Target gas:Ethanol/Halitosis/Acetaldehyde/Acetone/Isoprene
Target gas Acetone、Ethanol、Acetaldehyde、Isoprene
Description Acetone, ethanol, acetaldehyde and isoprene can be seperated and detected at the ppb level without cocentrating sample.
Measurement range Acetone 20-50000 ppb
Ethanol 200-100000 ppb
Acetaldehyde 5-10000 ppb
Isoprene 10-10000 ppb
Measuring time 8 min.
Carrier gas Filtered clean ambient air
Detector Semiconductor gas sensor
Sampling gas amount 5cc
Power supply AC 100V 
Current consumption Approx. 100VA  
Signal output USB
Size 260(W)×135(H)×435(D)mm
Weight 7.4kg
SGC(Sensor Gas Chromatograph) SGEA-P3-A
Related item
Exhaled breath bag
Application

SGC(Sensor Gas Chromatograph)
SGEA-P3-B

Usage:Automobile - Others/Research・Analysis - Enviromental measurement/Research・Analysis - Hydrogen embrittlement
Target gas:Acetaldehyde
Target gas Acetaldehyde
Description Acetaldehyde can be detected at the ppb level without cocentrating sample.
Measurement range Acetaldehyde 5-10000 ppb
Measuring time 8 min.
Carrier gas Filtered clean ambient air
Detector Semiconductor gas sensor
Sampling gas amount 5cc
Power supply AC 100V 
Current consumption Approx. 100VA  
Signal output USB
Size 260(W)×135(H)×435(D)mm
Weight 7.4kg
SGC(Sensor Gas Chromatograph) SGEA-P3-B
Related item
Exhaled breath bag
Application

SGC(Sensor Gas Chromatograph)
SGEA-P3-C1

Usage:Research・Analysis - Enviromental measurement/Research・Analysis - Hydrogen embrittlement
Target gas:Ethylene
Target gas Ethylene
Description Ethylene can be detected from 5 ppb without concentrating sample
Measurement range Ethylene 5-10000 ppb
Measuring time 4 min.
Carrier gas Filtered clean ambient air
Detector Semiconductor gas sensor
Sampling gas amount 5cc
Power supply AC 100V 
Current consumption Approx. 100VA  
Signal output USB
Size 260(W)×135(H)×435(D)mm
Weight 7.4kg
SGC(Sensor Gas Chromatograph) SGEA-P3-C1
Related item
Application

SGC(Sensor Gas Chromatograph)
SGEA-P3-C2

Usage:Research・Analysis - Enviromental measurement/Research・Analysis - Hydrogen embrittlement
Target gas:Ethylene/Acetaldehyde
Target gas Ethylene、Acetaldehyde
Description Ethylene and acetaldehyde can be seperated and detected at the ppb level without cocentrating sample.
Measurement range Ethylene 50-10000 ppb
Acetaldehyde 100-10000 ppb
Measuring time 8 min.
Carrier gas Filtered clean ambient air
Detector Semiconductor gas sensor
Sampling gas amount 5cc
Power supply AC 100V 
Current consumption Approx. 100VA  
Signal output USB
Size 260(W)×135(H)×435(D)mm
Weight 7.4kg
SGC(Sensor Gas Chromatograph) SGEA-P3-C2
Related item
Application

PDHA-1000、PDHA-2000、PDHA-3000

Usage:Automobile - Others/Research・Analysis - Enviromental measurement/Research・Analysis - Hydrogen embrittlement
Target gas:H2
Target gas H2
Description This device can analyze the temperature desorption of H2 at the ppb level, from room temperature to 600℃ (with PDHA-1000), 800℃(with PDHA-2000),1000℃(with PDHA-3000)under atmospheric pressure
Measurement range H2 10-10000 ppb
Measuring time 2 min.
Carrier gas Filtered clean ambient air
Detector Semiconductor gas sensor
Sampling gas amount 1cc
Power supply AC 100V 
Current consumption Approx. 1000VA(Total)
Signal output USB
Size 260(W)×135(H)×340(D)mm, other Please refer to the catalog
Weight Please refer to the catalog
PDHA-1000、PDHA-2000、PDHA-3000
Related item
Application

PDHA-4000

Usage:Automobile - Others/Research・Analysis - Enviromental measurement/Research・Analysis - Hydrogen embrittlement
Target gas:H2
Target gas H2
Description PDHA-4000 can analyze the temperature desorption of H2 at the ppb level, from -100℃ to 800℃ under atmospheric pressure
Measurement range H2 10-10000 ppb
Measuring time 2 min.
Carrier gas Filtered clean ambient air
Detector Semiconductor gas sensor
Sampling gas amount 1cc
Power supply AC 100V 
Current consumption Approx. 1000VA(Total)
Signal output USB
Size 260(W)×135(H)×340(D)mm, other Please refer to the catalog
Weight Please refer to the catalog
PDHA-4000
Related item

In the interest of continued product improvement, we reserve the right to change design features without prior notice.